DESCRIPTION
ORDERING CODE
Valves EVX-*-C5 are ATEX directional control valve in cartridge style poppet
type. It is suitable for 2 way metric cavity M22 x 1,5 or cavity SAE 08 . The valve
is available with ATEX metallic DC and AC solenoids. The coil is Zinc-nichel
coated for an enhanced surface protection (ISO 9227, 520 h salt spray).
Protection according to IEC 144: Class IP67- External surfaces zinc-nickel coat-
ed (min. thickness 7 micron)
Connection: 3,5 mm
2
wire cable (CEI 20-22), length 3 m already connected to coil.
Electrical connection must be accordance to Ex-proof norm ATEX. Earth
connection both internal, with yellow-green wire in the cable,and external with a
minimum 4mm
2
cable fastened to earth screw.
1
2
HYDRAULIC SCREW-IN VALVES proof II 2 GD, Ex db IIC T5 Gb & Ex tb IIIC T100 °C Db
EVX-*-C5/25
25 l/min 25 MPa (250 bar)
(1)
EVX - - - /
(3)
C5-
(2) (4) (5) (6)
25
(1) EVX: Ex-proof solenoid operated screw-in poppet valve
(2) Size:
06: metric cavity M22x1,5 See
5
34: SAE 08 cavity 3/4” 16 UNF See
5
(3) C5: two way type
(4) Coils:
012C: 12V DC-0,92A
024C: 24V DC-0,46A
115A: 115V AC-0,10A
230A: 230V AC-0,05A
(5) Cable lenght :
no designation: standard 3m cable
5: 5m
10: 10m
16: 16m
20: 20m
(6) /25: Design number of the valves Atex solenoid for G and D
1
2
TECHNICAL DATA
3
Suitable for standard cavity: M22 x 1,5 or SAE 08
Solenoids according to ATEX 94/9/CE and conform to EN 50281-1-1
ATEX code/class: II 2 GD Ex d III C T5
Certificate: INERIS 05ATEX0028X/02
Max. operating pressure: 250 bar
Max. flow rate: 25 l/min
Duty cycle: 100%
Materials: Steel body, poppet in tempered and grinded steel
Mass 1,40 kg (coil included)
27
85
144,8
45
61,5
5
65
110
97,8
117,8
20
Ch.24
1
2
V2-21
V2-21
6
www.aidro.it
0016
TYPICAL DIAGRAMS
4
Typical Δp-Q curves for valves EVX-*-C5 in standard configuration, with
mineral oil at 26 cSt and 50 °C
Typical p-Q curves of operating limits for maximum hydraulic power transferred
by valves EVX-*-C5
5 10 15 20 25 30
0
50
100
150
200
250
300
Pressure p in bar
Flow Q in l/min
0
5 10 15 20 25 30
5
10
15
20
Pressure Δp in bar
Flow Q in l/min
V2-21
6
INSTALLATION DIMENSIONS (mm)
5
EXPLOSION PROOF SOLENOID GMA-6/HD SERIES 271 GD
0: Ex proof solenoid according to ATEX 94/9/EC.
II 2GD Ex db IIC T5 Gb, Ex tb IIIC T100 °C Db IP66/67.
Solenoid outside surfaces are zinc-nickel plated, with 7µm minimum thickness
1: Solenoid label indicates supply voltage, protection class Ex d, certification
number by INERIS and maximum absorbed power.
2: 3-wires cable, according to CEI 20-22, of standard length of 3 m, is fas-
tened to the coil and locked by cable gland.
3: Wires have 1,5 mm
2
section; earth connection wire is green-yellow.
Electric connection must be in accordance with Ex-proof norm ATEX.
4: Manual override operation is by pushing the extended pin.
5: Normalised cable gland –torque 8 Nm ± 1 – device has threaded
attachment ½” conical – ISO 7/1
6: Earth connection screw
7: Threaded plug (socket hexagon 1,5 mm)to lock the retaining coil nut 
8: Nut for retaining the coil –torque 6 Nm ± 1 – hexagon 24 mm.
Conformity of unit to the norms is not granted if coil is used
separately from its electromagnetic tube.
Atex Certificates :
INERIS 05ATEX0028X/02 for Gas and Dust